Control box boiler level RL30/2S/3R
SKU: A108Our most widely applicable control box, this 10-pin box is for machines with detection of the water level in the reservoir. When used to replace a 9-pin box, you can leave the LAMP connection out of use, and with an 8-pin box, EVEROG can also be left out of use.
When used with a machine without detection for the water tank on the box, such as Isomac or Expobar, you can connect pole 1 to earth (3). See the 2nd photo. For this you can make a bridge with a double cable lug, a single one and a piece of wire.
Gigar code 9.1.40.61G
You can always send a photo of your current box with a clear identification plate. Then we can advise you.
1 = Water tank probe /switch
2 = boiler level probe
3 = ground/frame
4 = Switch brewgroup
5 = Resictance / pressure switch
6 = Solenoid boiler
7 = Pump
8 = Commune
9 = Lamp
10 = Fase